Карточка уязвимости
Характеристики уязвимости
Уровень опасности
Оценка CVSS
Производитель ПО
Наименование ПО
SAP Notes
(1676848-2)
SAP Support Packages
(712, SAPKU51006, SAPKU52011, SAPKU60012, SAPKU70012, SAPKU70109, SAPKU70203)
Описание
BSP Page CRM_IC_AUTO/RuntimeRepository.xml within Application Component CRM-IC-OBJ do not sufficiently encode OUTPUT parameters, resulting in a cross-site scripting issue.Cross-site scripting can be used to steal another user's authentication information, such as data relating to their current session. A malicious user who gains access to this data may use it to impersonate the user and access all information with the same rights as the target user.If an administrator is impersonated, the security of the application may be fully compromised
Как исправить
Please apply this note or import the changes via the relevant supportpackage.------------------------------------------------------------------------|Manual Post-Implement. |------------------------------------------------------------------------|VALID FOR ||Software Component BBPCRM BBP / CRM || Release 701 SAPKU70103 - SAPKU70108 |------------------------------------------------------------------------Comment out the following XML files: -VEHMNAVIGATIONALLINKS1RT.xml -VEHMNAVIGATIONALLINKS2RT.xml -VEHMNAVLINKSEVENTHISTORYRT.xmlThe files can be found and commented out by following the steps below:1) Go to transaction se80.2) Provide BSP Application CRM_IC_AUTO.3) Expand the node 'Page Fragments'.4) Double click on each of the XML files above and comment out the source code with the following syntax template <%-- Source Code here --%>
Ссылки